Reduction of Fungicide Emissions from the Foundry, Blast Furnace No. 2
A design subject was reconstruction of the existing dust removal system in the Foundry, Blast Furnace No. 2 (BF2),i.e. reconstruction of the existing dust removal station of the capacity of 650, 000 m3/h and discharge concentration of <30 mg/Nm3 for the identical flow rate capacity, however, of the discharge capacity <10 mg/Nm3. The dust removal station reconstruction comprises reconstruction of a cloth filter, compressor station, fans and motors. Further, the blast furnace 2 dust removal system reconstruction comprises installation of a new exhaustion system at the Foundry to collect pollutants produced during tapping and casting of pig iron.
Design works were carried out within joint venture of the companies NOVÁ HUŤ – Projekce, spol. s r.o. and Technoprojekt, a.s
CLIENT: | ArcelorMittal Ostrava a.s |
PROJECT IMPLEMENTATION: | 2012 – 2013 |
WORK SCOPE:
- Design concept;
- Planning permit documentation.